E+H Cerabar PMC21 Absolute/Gauge Pressure Transmitter

E+H Cerabar PMC21 Absolute/Gauge Pressure Transmitter
Details:
The E+H Cerabar PMC21 is a compact, cost-effective absolute and gauge pressure transmitter utilizing ceramic capacitive measurement technology, specifically designed for applications in water treatment, HVAC (Heating, Ventilation, and Air Conditioning), and general industrial processes. While ensuring reliable measurement performance, this product offers an ideal solution for routine pressure measurement needs with its ingenious design and economical pricing.
Send Inquiry
Description
Send Inquiry

Products Description

 

 

The E+H Cerabar PMC21 is a compact, cost-effective absolute and gauge pressure transmitter utilizing ceramic capacitive measurement technology, specifically designed for applications in water treatment, HVAC (Heating, Ventilation, and Air Conditioning), and general industrial processes. While ensuring reliable measurement performance, this product offers an ideal solution for routine pressure measurement needs with its ingenious design and economical pricing.

Core Technical Features

 

 

Feature

Detailed Description

Ceramic Capacitive Sensor

• High-performance ceramic measuring diaphragm with good chemical stability and corrosion resistance

• Oil-free design avoids temperature effects on fill fluid, ensuring long-term stability

Compact Integrated Design

• Small footprint, low installation space requirements

• Integrated process connection and electronics minimize potential leak points

High Accuracy & Stability

• Measurement accuracy up to ±0.5% (standard)

• Good temperature compensation performance adapts to environmental changes

Multiple Pressure Types

• Available in Absolute (a) and Gauge (g) measurement versions

• Gauge version includes atmospheric pressure compensation

Easy Operation

• Basic parameter setup via local push buttons

• Clear status indicators

Environmental Adaptability

• Protection rating IP67, dustproof and waterproof

• Wide operating temperature range: -40℃ to +85℃

Output & Communication

• 4~20mA HART standard output

• Compatible with mainstream control systems

Multiple Certifications

• CE, RoHS and other international certifications

• Compliant with industry application standards

Technical Specifications

 

 

Parameter Category

Technical Specifications

Measuring Range

Gauge: -1...0 bar to 0...400 bar Absolute: 0...1 bar to 0...400 bar

Accuracy Class

±0.5% (standard) Optional ±0.25% high-accuracy version

Long-term Stability

≤±0.5%/year

Operating Temperature

-40℃ to +85℃ (ambient) -40℃ to +100℃ (process)

Supply Voltage

10.5 to 45V DC (2-wire)

Output Signal

4~20mA HART

Process Connection

G1/2, 1/2" NPT, M20×1.5

Protection Rating

IP67

Response Time

<10ms (adjustable)

Overpressure Capability

Up to 4 times the measuring range

 

Industry Application Advantages

 

 

1. Excellent Cost Performance

· Competitive pricing within the same performance class

· Low maintenance requirements reduce operating costs

· Easy installation saves construction time

2. Wide Applicability

· Absolute and gauge versions cover most application scenarios

· Wide temperature range design adapts to different climate conditions

· Multiple process interfaces meet various installation needs

3. Reliable Measurement Performance

· Ceramic sensor ensures long-term stability

· Good interference resistance

· Consistent measurement accuracy

4. Easy Integration & Maintenance

· Standard signal output compatible with existing systems

· Modular design simplifies maintenance

· Intuitive operator interface

Suitable Application Scenarios

 

 

Water Treatment & Supply Systems

· Municipal Water Plants: Pump station discharge pressure monitoring

· Wastewater Treatment: Aeration tank pressure, sludge pump pressure

· Pipeline Monitoring: Water distribution network pressure control

· Secondary Water Supply: High-rise building water supply system pressure assurance

HVAC Systems

· Air Conditioning Systems: Chiller pressure, chilled water pressure

· Ventilation Systems: Fan static pressure measurement

· Clean Rooms: Pressure differential control (with DP transmitter)

· Building Automation: System-integrated pressure monitoring

General Industrial Processes

· Compressed Air: Compressor outlet pressure, network pressure

· Hydraulic Systems: Hydraulic power unit pressure monitoring

· Pneumatic Equipment: Working air pressure monitoring

· Process Control: Small reactor pressure

Machinery Equipment

· Construction Machinery: Hydraulic system pressure

· Injection Molding Machines: Injection pressure, clamping force

· Packaging Machinery: Pneumatic system pressure

· Testing Equipment: Pressure testing systems

Energy Management

· Boiler Auxiliaries: Feedwater pressure, steam pressure

· Heating Networks: District heating system pressure

· Solar Energy: Solar thermal system pressure

· Pump Station Monitoring: Pump inlet/outlet pressure

Installation & Configuration

 

 

Installation Guidelines

1. Location Selection: Avoid positions with strong vibration and rapid temperature changes

2. Mounting Orientation: Process connection facing downward to prevent condensate accumulation

3. Electrical Connection: Use shielded cables with proper grounding

4. Process Connection: Ensure proper sealing using appropriate tools

Parameter Setup

· Local Setup: Set range, units via device buttons

· HART Setup: Advanced parameter configuration using handheld communicator

· Factory Settings: Standard configuration provided for most applications

Maintenance Recommendations

· Routine Checks: Visual inspection, signal verification

· Regular Calibration: Annual zero-point calibration recommended

· Cleaning: Keep device clean, check seals

· Troubleshooting: Utilize HART diagnostic functions

Selection Guide

 

 

Selection Key Points

1. Pressure Type: Choose absolute or gauge based on requirements

2. Measuring Range: Select range covering 1.5-2 times working pressure

3. Process Connection: Match on-site pipeline interface standards

4. Environmental Requirements: Consider temperature, protection rating

5. Output Requirements: Confirm control system interface type

Model Configuration

· PMC21-A: Absolute pressure version

· PMC21-G: Gauge pressure version

· Optional accuracy classes

· Optional process connection types

· Optional electrical interface forms

Core Keywords

 

 

1. Compact Pressure Transmitter

2. Ceramic Capacitive Pressure Sensor

3. E+H Cerabar PMC21

4. Absolute/Gauge Pressure Transmitter

5. Water Treatment Pressure Measurement

6. HVAC Pressure Sensor

7. Industrial Process Pressure Monitoring

8. Economical Pressure Transmitter

9. HART Communication Pressure Instrument

10. General Industrial Pressure Measurement

Hot Tags: e+h cerabar pmc21 absolute/gauge pressure transmitter, China e+h cerabar pmc21 absolute/gauge pressure transmitter suppliers, factory, iot pressure transmitter, pressure control sensor, wireless pressure transducer, pt pressure transducer, ceramic diaphragm pressure transmitter, diaphragm seal transmitter