Product introduction:
The Rosemount 3051S MultiVariable Transmitter is a best-in-class solution customized to obtain measurement combinations of differential pressure, static pressure and process temperature. This multivariable transmitter is a cost-effective device that reduces pipe penetrations, impulse piping and connection systems. This device is also engineered with built-in flow calculations for fully compensated mass flow measurements.
Product feature:
- Measures multiple variables and standardizes on a single model number for streamline process and cost-efficiency
- Reduces costs by eliminating the need for stacked transmitters and additional wiring
- Primary elements available as assemble-to options for simple installation and commissioning
- Multivariable design reduces pipe penetrations, impulse piping and connection systems for cost-savings
- Callendar-Van Dusen sensor matching improves temperature accuracy enabling best-in-class flow calculations
- All-welded, SuperModule™ design offers industry-leading accuracy in harsh environments and applications
- Engineering Assistant Software allows for configuration in two easy steps
- Ultra for Flow provides optimized flow readings with a ±0.04% of reading accuracy
- Designed with built-in flow calculations for direct reporting of fully-compensated mass, energy or volumentric flow
Product Parameter:
|
Model |
|
|
Code |
Description |
|
3144P |
Temperature transmitter |
|
Transmitter output |
|
|
Code |
Description |
|
A |
4-20 mA with digital signal based on HART® Protocol |
|
F |
FOUNDATION Fieldbus digital signal (includes three analog input function block and backup link active scheduler) |
|
Measurement configuration |
|
|
Code |
Description |
|
1 |
Single-sensor input |
|
2 |
Dual-sensor input |
|
Housing style |
|||
|
Code |
Description |
Material |
Conduit entry size |
|
D1 |
Field mount housing, dualcompartment housing |
Aluminum |
½-14-inch NPT |
|
D2 |
Field mount housing, dualcompartment housing |
Aluminum |
M20 x1.5(CM20) |
|
D3 |
Field mount housing, dualcompartment housing |
Aluminum |
PG 13.5 (PG11) |
|
D4 |
Field mount housing, dualcompartment housing |
Aluminum |
JIS G ½ |
|
D5 |
Field mount housing, dualcompartment housing |
Stainless steel |
½-14-inch NPT |
|
D6 |
Field mount housing, dualcompartment housing |
Stainless steel |
M20 x1.5(CM20) |
|
D7 |
Field mount housing, dualcompartment housing |
Stainless steel |
PG 13.5 (PG11) |
|
D8 |
Field mount housing, dualcompartment housing |
Stainless steel |
JIS G ½ |
|
D9 |
Field mount housing, dualcompartment housing |
Aluminum, ultra low copper |
½-14-inch NPT |
|
D0 |
Field mount housing, dualcompartment housing |
Aluminum, ultra low copper |
M20 x1.5(CM20) |
|
Product certifications |
|
|
Code |
Description |
|
NA |
No approval |
|
E5 |
USA explosion-proof, dust ignition-proof, and non-incendive |
|
I5 |
USA intrinsically Safe (iS) and non-incendive (includes standard is and FisCo for Fieldbus units) |
|
K5 |
USA IS, non-incendive, and explosion-proof combination (includes standard iS and FisCO for fieldbus units) |
|
KB |
USA and Canada is, explosion-proof, and non-incendive combination (includes standard is and FiscO for fieldbusunits) |
|
I6 |
Canada IS/FISCO, and Division 2 (includes standard is and FisCO for fFieldbus units) |
|
K6 |
Canada is, FISCO Division 2, and explosion-proof combination (includes standard iS, FISCO for Fieldbus units) |
|
E1 |
ATEX fameproof approval |
|
N1 |
ATEX type n approval |
|
I1 |
ATEX intrinsic safety approval (includes standard is and FISCO for Fieldbus units) |
|
K1 |
ATEX is, flameproof, dust ignition-proof and type n combination (includes standard is and FISCO for fieldbus units) |
|
ND |
ATEX dust ignition-proof approval |
|
KA |
ATEX/Canada intrinsic safety, explosion-proof combination (includes standard is and FISCO for fieldbus units) |
|
E7 |
IECEx fameproof approval |
|
N7 |
IECEx Type 'n' approval |
|
I7 |
IECEx intrinsic safety |
|
K7 |
IECEx intrinsic safety, flameproof, dust ignition-proof and type n combination |
|
E2 |
Brazil flameproof |
|
I2 |
Brazil intrinsic safety |
|
E4 |
japan flameproof approval |
|
E3 |
China fameproof approval |
|
I3 |
China intrinsic safety |
|
N3 |
China type n |
|
KM |
Technical Regulations Customs Union (EAC) flameproof, intrinsic safety |
|
IM |
Technical Regulations Customs Union (EAC) intrinsic safety |
|
EM |
Technical Regulations Customs Union (EAC) flameproof |
|
IP |
Korean intrinsic Safety |
|
EP |
Korean Flameproof |
|
KP |
Korean Intrinsic Safety, Flameproof |
Figure 2: Transmitter exploded view
A. Cover with wiring diagram
B. Name plate
C. Electronic module
LCD display
E. Display cover
F. Housing with permanent terminal block

Figure 4: Transmitter view
A. Conduit entry
B. Display cover
C. Name plate

Figure 6: Pipe mounting configurations with optional mounting bracket
A. For transmitter mounting
B.2-in. U-bolt for pipe mounting
Note
Dimensions are in inches (millimeters)

Figure 7: Rosemount X-well Assembly with Universal Pipe Mount


Hot Tags: rosemount 3051 multivariable transmitter, China rosemount 3051 multivariable transmitter suppliers, factory, flare gas flow meter, ultrasonic mass flow meter, best water flow meter, sierra mass flow controller, 1 4 flow meter, ege flow sensor