Product introduction:
The Rosemount 3051S MultiVariable Transmitter is a best-in-class solution customized to obtain measurement combinations of differential pressure, static pressure and process temperature. This multivariable transmitter is a cost-effective device that reduces pipe penetrations, impulse piping and connection systems. This device is also engineered with built-in flow calculations for fully compensated mass flow measurements.
Product feature:
- Measures multiple variables and standardizes on a single model number for streamline process and cost-efficiency
- Reduces costs by eliminating the need for stacked transmitters and additional wiring
- Primary elements available as assemble-to options for simple installation and commissioning
- Multivariable design reduces pipe penetrations, impulse piping and connection systems for cost-savings
- Callendar-Van Dusen sensor matching improves temperature accuracy enabling best-in-class flow calculations
- All-welded, SuperModule™ design offers industry-leading accuracy in harsh environments and applications
- Engineering Assistant Software allows for configuration in two easy steps
- Ultra for Flow provides optimized flow readings with a ±0.04% of reading accuracy
- Designed with built-in flow calculations for direct reporting of fully-compensated mass, energy or volumentric flow
Product Parameter:
|
Model |
|
|
Code |
Description |
|
3144P |
Temperature transmitter |
|
Transmitter output |
|
|
Code |
Description |
|
A |
4-20 mA with digital signal based on HART® Protocol |
|
F |
FOUNDATION Fieldbus digital signal (includes three analog input function block and backup link active scheduler) |
|
Measurement configuration |
|
|
Code |
Description |
|
1 |
Single-sensor input |
|
2 |
Dual-sensor input |
|
Housing style |
|||
|
Code |
Description |
Material |
Conduit entry size |
|
D1 |
Field mount housing, dualcompartment housing |
Aluminum |
½-14-inch NPT |
|
D2 |
Field mount housing, dualcompartment housing |
Aluminum |
M20 x1.5(CM20) |
|
D3 |
Field mount housing, dualcompartment housing |
Aluminum |
PG 13.5 (PG11) |
|
D4 |
Field mount housing, dualcompartment housing |
Aluminum |
JIS G ½ |
|
D5 |
Field mount housing, dualcompartment housing |
Stainless steel |
½-14-inch NPT |
|
D6 |
Field mount housing, dualcompartment housing |
Stainless steel |
M20 x1.5(CM20) |
|
D7 |
Field mount housing, dualcompartment housing |
Stainless steel |
PG 13.5 (PG11) |
|
D8 |
Field mount housing, dualcompartment housing |
Stainless steel |
JIS G ½ |
|
D9 |
Field mount housing, dualcompartment housing |
Aluminum, ultra low copper |
½-14-inch NPT |
|
D0 |
Field mount housing, dualcompartment housing |
Aluminum, ultra low copper |
M20 x1.5(CM20) |
|
Product certifications |
|
|
Code |
Description |
|
NA |
No approval |
|
E5 |
USA explosion-proof, dust ignition-proof, and non-incendive |
|
I5 |
USA intrinsically Safe (iS) and non-incendive (includes standard is and FisCo for Fieldbus units) |
|
K5 |
USA IS, non-incendive, and explosion-proof combination (includes standard iS and FisCO for fieldbus units) |
|
KB |
USA and Canada is, explosion-proof, and non-incendive combination (includes standard is and FiscO for fieldbusunits) |
|
I6 |
Canada IS/FISCO, and Division 2 (includes standard is and FisCO for fFieldbus units) |
|
K6 |
Canada is, FISCO Division 2, and explosion-proof combination (includes standard iS, FISCO for Fieldbus units) |
|
E1 |
ATEX fameproof approval |
|
N1 |
ATEX type n approval |
|
I1 |
ATEX intrinsic safety approval (includes standard is and FISCO for Fieldbus units) |
|
K1 |
ATEX is, flameproof, dust ignition-proof and type n combination (includes standard is and FISCO for fieldbus units) |
|
ND |
ATEX dust ignition-proof approval |
|
KA |
ATEX/Canada intrinsic safety, explosion-proof combination (includes standard is and FISCO for fieldbus units) |
|
E7 |
IECEx fameproof approval |
|
N7 |
IECEx Type 'n' approval |
|
I7 |
IECEx intrinsic safety |
|
K7 |
IECEx intrinsic safety, flameproof, dust ignition-proof and type n combination |
|
E2 |
Brazil flameproof |
|
I2 |
Brazil intrinsic safety |
|
E4 |
japan flameproof approval |
|
E3 |
China fameproof approval |
|
I3 |
China intrinsic safety |
|
N3 |
China type n |
|
KM |
Technical Regulations Customs Union (EAC) flameproof, intrinsic safety |
|
IM |
Technical Regulations Customs Union (EAC) intrinsic safety |
|
EM |
Technical Regulations Customs Union (EAC) flameproof |
|
IP |
Korean intrinsic Safety |
|
EP |
Korean Flameproof |
|
KP |
Korean Intrinsic Safety, Flameproof |
Figure 2: Transmitter exploded view
A. Cover with wiring diagram
B. Name plate
C. Electronic module
LCD display
E. Display cover
F. Housing with permanent terminal block

Figure 4: Transmitter view
A. Conduit entry
B. Display cover
C. Name plate

Figure 6: Pipe mounting configurations with optional mounting bracket
A. For transmitter mounting
B.2-in. U-bolt for pipe mounting
Note
Dimensions are in inches (millimeters)

Figure 7: Rosemount X-well Assembly with Universal Pipe Mount


Hot Tags: rosemount 3051 multivariable transmitter, China rosemount 3051 multivariable transmitter suppliers, factory, liquid nitrogen flow meter, magnetic water flow switch, rotor flow meter, water current meter, water flow measurement, water velocity measurement instruments